Vapor Pressure Calculator
Enter a known vapor pressure and temperature, the heat of vaporization and a new temperature to find the new vapor pressure.
What this calculator returns
The output is the vapour pressure at the new temperature, in the same units as the known pressure you enter. At the defaults — 101.325 kPa at 373.15 K (100°C), ΔHvap = 40,660 J/mol and a new temperature of 363.15 K (90°C) — it returns 70.63 kPa.
That is a 30% drop in pressure for a 10 K drop in temperature, which is the practical message of the whole tool: vapour pressure is steeply sensitive to temperature, and the steepness is set by the heat of vaporization.
The equation and its terms
P1 and P2 are the two vapour pressures, T1 and T2 the matching absolute temperatures in kelvin, ΔHvap the molar heat of vaporization in J/mol, and R = 8.314 J/(mol·K). Water’s 40,660 J/mol is the energy needed to turn one mole of liquid into vapour at its boiling point.
The form the calculator actually evaluates is P2 = P1 · exp[−(ΔHvap÷R)(1/T2 − 1/T1)]. If T2 is below T1, the bracket is positive, the exponent is negative and the pressure falls; above T1 it rises. The signs take care of themselves, which is why a wrong answer usually means a Celsius temperature crept in.
Why the reciprocal temperatures appear
The derivation integrates d(ln P) = (ΔHvap ÷ RT²) dT between the two states, and the integral of 1/T² is −1/T. That is where the difference of reciprocals comes from, and it is also why a plot of ln P against 1/T is a straight line whose slope is −ΔHvap÷R. Two measured points are enough to find the heat of vaporization, which is how the value for a new compound is usually obtained.
Worked example at the defaults
ΔHvap ÷ R = 40,660 ÷ 8.314 = 4,890.6 K. Reciprocal temperatures: 1 ÷ 363.15 = 0.0027537 K−1 and 1 ÷ 373.15 = 0.0026799, a difference of 0.0000738. Multiply: 4,890.6 × 0.0000738 = 0.3608. Then exp(−0.3608) = 0.6972, and 101.325 × 0.6972 = 70.63 kPa.
Read the result as a boiling point. Water boils where its vapour pressure equals the surrounding pressure, so 70.63 kPa corresponds to a boiling point of 90°C. That is roughly the pressure at 3,000 m of altitude, and the reason a pot of water there cooks food about 25% slower.
Water vapour pressure from 70 to 120°C
| Temperature | Kelvin | Vapour pressure |
|---|---|---|
| 70°C | 343.15 K | 32.2 kPa |
| 80°C | 353.15 K | 48.2 kPa |
| 90°C | 363.15 K | 70.6 kPa |
| 100°C | 373.15 K | 101.3 kPa |
| 120°C | 393.15 K | 197.4 kPa |
Every 10 K step multiplies the pressure by roughly 1.5 below 100°C and by about 1.9 above it, which is why pressure cookers reach 120°C at 197 kPa and cut cooking times for beans and stews by two thirds. The curve is exponential, not linear, so interpolating between rows gives the wrong answer outside a narrow band.
What moves the number
- Heat of vaporization: raising ΔHvap from 40,660 to 44,000 J/mol lowers the 90°C result to 68.6 kPa, because the liquid holds its molecules more tightly.
- New temperature: 80°C instead of 90°C drops the answer from 70.6 to 48.2 kPa.
- Reference point: an error of 1 K in T1 shifts P2 by about 3.5% at these conditions.
- Molar basis: using 2,260 J/mol (the per-gram value) instead of 40,660 produces a pressure barely above the reference.
Boiling point and altitude
At sea level the atmosphere pushes 101.3 kPa and water boils at 100°C. At 2,000 m the pressure is near 79.5 kPa and the boiling point falls to roughly 93°C; at 3,000 m, 70.6 kPa gives 90°C. The same arithmetic explains why a vacuum pump can boil water at room temperature: drop the pressure to 2.3 kPa and 20°C water is already at its boiling point.
Mistakes that break the calculation
- Entering Celsius. The equation needs kelvin, and 90 instead of 363.15 produces a nonsensical exponent.
- Flipping the temperature difference, which inverts the ratio and reports 145 kPa instead of 70.6.
- Mixing kJ/mol with J/mol, a factor of 1,000 that drives the result to either the reference pressure or near zero.
- Treating ΔHvap as constant over hundreds of kelvin. It falls as the critical point approaches, so the two-point form is unreliable across a wide range.
The constant-ΔH assumption is the one worth respecting. Between 70°C and 120°C water’s heat of vaporization drops from about 42.4 to 39.7 kJ/mol, which is why the equation’s 197 kPa at 120°C sits just below the measured 198.5 kPa. Over a 200 K span the error grows to double digits.
Where the result is used
Distillation columns set their operating pressure from this curve, so a vacuum column can separate heat-sensitive compounds at 60°C instead of 140°C. Humidity calculations need the saturation vapour pressure at the current temperature, and engine intake models need it to predict fuel vaporization.
For the gas-phase behaviour once the vapour has formed, the ideal gas law calculator takes over with the partial pressure you just found.
Frequently asked questions
What is the Clausius-Clapeyron equation?
ln(P2/P1) = −(ΔHvap/R)(1/T2 − 1/T1). For water going from 100°C to 90°C it returns 70.63 kPa from a 101.325 kPa reference.
Why does vapour pressure rise with temperature?
More molecules have enough thermal energy to escape the liquid. The rise is exponential, roughly 1.5-fold per 10 K near 90°C: 48.2 kPa at 80°C becomes 70.6 at 90°C.
When does a liquid boil?
When its vapour pressure equals the external pressure. At 70.63 kPa water boils at 90°C, and at sea level where the pressure is 101.3 kPa it boils at 100°C.
Why does water boil at a lower temperature at altitude?
The atmosphere pushes less. At 3,000 m the pressure is about 70.6 kPa, so water boils at 90°C; at 2,000 m and 79.5 kPa it boils near 93°C.
What numbers do I enter for water?
Use 101.325 kPa at 373.15 K, ΔHvap = 40,660 J/mol, and the new temperature in kelvin. A 363.15 K target gives 70.63 kPa, which is 30% lower than the reference.
Can I use Celsius in the formula?
No. The reciprocals require absolute temperature; 90 instead of 363.15 makes the exponent about 4,900 times too large and the result meaningless.
What happens in a pressure cooker?
Raising the pressure to 197 kPa lifts the boiling point to 120°C, so food cooks faster. That is the same table row read in reverse.
Is the heat of vaporization constant?
No. Water falls from 42.4 kJ/mol at 70°C to 39.7 kJ/mol at 120°C, so the equation drifts slightly: it predicts 197.4 kPa at 120°C against a measured 198.5 kPa.
Why is my answer inverted?
You subtracted the temperatures the other way round. Reversing 1/T2 − 1/T1 turns 70.6 kPa into 145 kPa, roughly the pressure at 110°C instead of 90°C.
What unit should the pressure be in?
Any consistent unit. The equation uses a ratio, so 101.325 kPa, 1 atm or 760 mmHg all give 70.63 when the temperature inputs are correct.
Method and sources
- Clausius-Clapeyron equation ln(P2/P1) = −(ΔHvap/R)(1/T2 − 1/T1); R = 8.314 J/(mol·K).