Decibel Calculator
Enter a sound intensity to find its level in decibels.
What this calculator returns
The tool converts a sound intensity in W/m² into a level in decibels and also reports the raw intensity ratio I ÷ I0. At the defaults, 10−6 W/m² against a reference of 10−12 W/m² gives 60 dB and a ratio of 1,000,000.
Why the scale is logarithmic
The quietest sound you can hear is about 10−12 W/m²; a jet engine at close range is around 100 W/m². That is a range of 1014 in a single quantity, which is unreadable as a linear number. Taking a base-10 logarithm turns that span into 0 to 140, a scale you can hold in your head.
The multiplier of 10 in front of the log is not arbitrary. It makes the bel — one log unit — into ten decibels, which is a convenient step size for audio work. Change the reference I0 and every reading shifts by a constant: doubling I0 to 2 × 10−12 would drop the default reading from 60 dB to 57 dB.
Two rules worth memorising
- Every +10 dB is a tenfold increase in intensity: 60 dB to 70 dB means 10−6 rises to 10−5 W/m².
- Every +3 dB is roughly a doubling of intensity: 60 dB to 63 dB takes 1 × 10−6 to 2 × 10−6 W/m².
- Going the other way, −3 dB halves the intensity and −10 dB cuts it to a tenth.
Worked example at the defaults
Start with I = 10−6 W/m² and I0 = 10−12 W/m². The ratio is 10−6 ÷ 10−12 = 106 = 1,000,000, and log10(106) = 6. Multiply by 10 and the level is 60 dB.
Now double the intensity to 2 × 10−6 W/m². The ratio becomes 2,000,000 and the level rises to 63.01 dB, a change of 3.01 dB for a doubling. Quadruple it to 4 × 10−6 and you get 66.02 dB, which is two 3 dB steps, exactly as the rule predicts.
To reach 90 dB you need a ratio of 109, so the intensity must be 10−3 W/m² — a thousand times the default. A 20 dB jump always means a hundredfold change in intensity, which is why small-looking dB differences matter so much when you specify equipment.
Levels, intensity and familiar sounds
| Level (dB) | Intensity (W/m²) | Ratio I/I0 | Typical source |
|---|---|---|---|
| 0 | 1 × 10−12 | 1 | Threshold of hearing |
| 30 | 1 × 10−9 | 1,000 | Quiet whisper |
| 60 | 1 × 10−6 | 1,000,000 | Normal conversation |
| 85 | 3.2 × 10−4 | 3.2 × 108 | 8-hour workplace limit |
| 90 | 1 × 10−3 | 1 × 109 | Lawn mower |
| 120 | 1 | 1 × 1012 | Threshold of pain |
| 140 | 100 | 1 × 1014 | Jet engine at close range |
Loudness is not intensity
Doubling the intensity adds 3 dB, but listeners report a doubling of loudness only around +10 dB. The ear compresses a 106 range of intensity into a subjective range of roughly 120 steps, which is why a 60 dB office and a 70 dB street sound like a modest difference and not a tenfold one.
What moves the reading
- Source power: doubling the intensity adds 3.01 dB, whatever the starting level.
- Distance: doubling the distance from a point source in free space quarters the intensity, a drop of 6.02 dB.
- Two identical incoherent sources: +3 dB, because intensities add.
- Two identical coherent sources: up to +6 dB, because pressures add before squaring.
- Reference intensity: halving I0 adds 3.01 dB to every reading on the page.
Decibels for pressure and for digital audio
This page uses intensity, so the multiplier is 10. Sound level meters work from pressure and use 20 log10(p ÷ p0) with p0 = 20 µPa. The two forms agree for a plane wave, and 94 dB SPL corresponds to a pressure of 1 Pa, which is the usual sensitivity reference for microphones.
Digital audio uses a third reference. dBFS measures how far a sample sits below full scale, so 0 dBFS is the clip point and every −6 dBFS is half the amplitude. Mixing up 10 log and 20 log is the classic way to be out by a factor of two on every conversion.
Mistakes that give the wrong number
Decibels add, intensities multiply — but only if you are combining sources correctly. Two 60 dB machines do not make 120 dB; they make 63 dB, because 10−6 + 10−6 = 2 × 10−6 W/m². Adding the dB values is the single most common error in noise assessments.
The second trap is a negative result. An intensity below the reference gives a negative level, which is mathematically fine — 10−13 W/m² is −10 dB — but a reading well below 0 dB usually means the reference is wrong rather than that the sound is unmeasurably quiet. Check I0 first.
Exposure limits in decibels
Workplace rules use a 3 dB exchange rate: 85 dB is allowed for 8 hours, 88 dB for 4 hours, 91 dB for 2 hours and 94 dB for 1 hour. At 100 dB the same daily dose is used up in 15 minutes. Each 3 dB step halves the safe time, which follows directly from the doubling of intensity.
Frequently asked questions
What is the formula for decibels?
The level is L = 10 log10(I ÷ I0), with I0 normally 10−12 W/m². An intensity of 10−6 W/m² gives 10 × log10(106) = 60 dB.
How much louder is a 10 dB increase?
Ten decibels is a tenfold increase in intensity. Going from 60 dB to 70 dB takes the intensity from 10−6 to 10−5 W/m².
Is a 3 dB increase twice as loud?
It is twice the intensity, not twice the perceived loudness. Doubling the intensity moves 60 dB to 63.01 dB, while listeners need about +10 dB to hear a doubling.
What does 0 dB mean if there is still sound?
0 dB simply means the intensity equals the reference, 10−12 W/m². It is the nominal threshold of hearing, not silence, and levels below it are negative.
How do I add two sound sources?
Convert each level to intensity, add the intensities, then convert back. Two 60 dB sources give 2 × 10−6 W/m², which is 63.01 dB, not 120 dB.
What is the difference between dB and dB SPL?
dB is a bare ratio. dB SPL pins the reference to 20 µPa of sound pressure, so 94 dB SPL is 1 Pa. This calculator uses an intensity reference of 10−12 W/m².
How far does sound drop with distance?
In free space, doubling the distance spreads the same power over four times the area, so the level falls by 6.02 dB. Moving from 1 m to 10 m costs 20 dB.
Why does my meter read 85 dB but the calculator says 60?
A meter reading near 85 dB corresponds to about 3.2 × 10−4 W/m². A 60 dB result means the intensity entered was 10−6 W/m², a thousand times lower.
How long can you safely listen at 100 dB?
About 15 minutes a day under the 3 dB exchange rule. At 85 dB the allowance is 8 hours, and every extra 3 dB halves the permitted time.
Method and sources
- Sound level L = 10 log10(I/I0); standard reference I0 = 10⁻¹² W/m².