CalcSeed

Charles's Law Calculator

Solve Charles’s law for any one of the four quantities, given the other three. Temperatures are in kelvin.

=
Quick answer: with the default inputs (1 L, 300 K, 600 K), the final volume is 2 L. Change any input to update the result.
Final volume
—

What Charles’s law describes

Charles’s law covers a sealed gas at constant pressure: heat it and it expands, cool it and it contracts, in direct proportion to absolute temperature. This calculator returns the missing one of four values — two volumes and two temperatures — and takes kelvin as its temperature unit throughout.

V1T1=V2T2 rac{V_1}{T_1} = rac{V_2}{T_2}

The ratio of volume to temperature is the constant, not the product. Double the absolute temperature and the volume doubles; there is no square root and no inverse, which is what separates Charles’s law from Boyle’s.

Pressure must stay fixed for this to hold, and the amount of gas must be sealed. A balloon is the classic example because the rubber keeps the inside pressure close to the outside atmosphere while the volume is free to change.

Why kelvin is not optional

Absolute temperature starts at absolute zero, the point where molecular motion reaches its minimum. Celsius starts at the freezing point of water, which is arbitrary from the gas’s point of view. A ratio of Celsius values has no physical meaning, and using one produces answers that are wrong by a large factor.

The trap is easy to fall into. Take a gas at 27 °C and heat it to 327 °C. In Celsius the number grew twelvefold, so a naive calculation turns 1 L into 12.1 L. In kelvin the same change is 300 K to 600 K, exactly double, and the correct answer is 2 L. The Celsius route overstates the volume by a factor of six.

Convert by adding 273.15: 0 °C is 273.15 K, 20 °C is 293.15 K, 37 °C is 310.15 K and 100 °C is 373.15 K. Rounding 273.15 to 273 introduces a 0.05% error, which is fine for a homework problem and not fine for a calibration.

Worked example at the defaults

The defaults are 1 L at 300 K, warmed to 600 K. The ratio is 1 ÷ 300 = 0.00333 L/K. Multiply by the new temperature: 0.00333 × 600 = 2 L, which is what the calculator returns.

The temperature doubled, so the volume doubled, and that is the entire content of the law. If you had 5 L at 300 K instead, the same heating would take it to 10 L, because the starting ratio 5 ÷ 300 is five times larger and everything scales with it.

Cooling runs the same arithmetic in reverse. Take the 2 L at 600 K down to 250 K and the volume becomes 2 × 250 ÷ 600 = 0.833 L, a little under a litre. Nothing special happens at the freezing point of water, because the gas does not care where Celsius put its zero.

Volume against temperature at constant pressure

Temperature (K)Temperature (°C)Volume (L)V ÷ T (L/K)
150−1230.500.00333
250−230.830.00333
300271.000.00333
350771.170.00333
4501771.500.00333
6003272.000.00333

The right column never moves, which is the whole test of whether a data set obeys the law. The Celsius column is there to show why it is useless as an input: the same 0.83 L appears at −23 °C, and a ratio built from that number would be negative for anything below freezing.

Where the law shows up in practice

  • Hot air balloons: heating the envelope from 300 K to 373 K expands the air by 24%, which is the density drop that generates lift.
  • Sealed containers in sunlight: a 20 L drum at 293 K reaching 333 K wants 13.7% more volume and bulges or vents instead.
  • Gas metering: a 40 °C swing between winter and summer moves the volume of a fixed mass of gas by about 13%, which is why meters correct to a reference temperature.
  • Baking and brewing: dough and wort volumes track temperature closely enough that proofing rooms are held within a degree or two.
  • Cryogenic handling: liquid nitrogen boil-off is Charles’s law plus a phase change, and the volume ratio from 77 K to 300 K is nearly 4 to 1.

The temperature conversions you will need

CelsiusKelvinTypical use
−40233.15Cold chamber test
0273.15Ice point
20293.15Laboratory ambient
25298.15Standard reference temperature
37310.15Body temperature
100373.15Boiling water

The standard reference temperature of 298.15 K is the one most gas-law problems mean when they say room temperature. Using 300 K instead is a 0.6% error, small but not zero, and it is the reason textbook answers and quick estimates differ in the third digit.

Mistakes and where the law breaks

  • Entering Celsius, the single most common error, which can invert or inflate the answer.
  • Treating the ratio as a product, which gives V&sub1;T&sub1; = V&sub2;T&sub2; and doubles the volume where it should halve.
  • Forgetting that pressure must stay constant: a rigid sealed tank is constant volume, so Gay-Lussac’s law applies instead.
  • Assuming the gas stays gaseous: cool below the dew point and the volume collapses far faster than the law predicts.

Why the line never quite reaches zero

Extrapolate volume against temperature to zero volume and you land at −273.15 °C, which is how absolute zero was first estimated. Real gases liquefy long before that, so the straight line only holds over the range where the substance is a gas. For air at atmospheric pressure that is roughly 80 K to 1,000 K, and this calculator happily accepts inputs outside that window while the physics quietly stops cooperating.

The three gas laws fit together

Hold temperature and you get Boyle’s law, where P×V is constant. Hold pressure and you get Charles’s law, where V ÷ T is constant. Hold volume and you get Gay-Lussac’s law, where P ÷ T is constant. Relax all three at once and the combined gas law covers it with P&sub1;V&sub1;/T&sub1; = P&sub2;V&sub2;/T&sub2;, of which this page is the constant-pressure slice.

Frequently asked questions

What does Charles’s law state?

At constant pressure, gas volume is directly proportional to absolute temperature, so V ÷ T stays fixed. Doubling 300 K to 600 K doubles 1 L to 2 L.

Why must temperature be in kelvin?

Because the law uses a ratio of absolute temperatures. Celsius has an arbitrary zero, so 27 °C to 327 °C looks twelvefold but is only 300 K to 600 K, a doubling.

How do I convert Celsius to kelvin?

Add 273.15. So 25 °C is 298.15 K and 100 °C is 373.15 K. Using 273 instead introduces a 0.05% error, about 0.1 mL on a litre.

What volume does 1 L at 300 K reach at 450 K?

1 × 450 ÷ 300 = 1.5 L, a 50% expansion for a 50% rise in absolute temperature.

What happens if I use Celsius by mistake?

The answer is badly wrong. The 27 °C to 327 °C case gives 12.1 L instead of 2 L, a factor of six too high.

Is Charles’s law the same as Gay-Lussac’s?

No. Charles’s law relates volume and temperature at constant pressure, while Gay-Lussac’s relates pressure and temperature at constant volume. Both use the same kelvin requirement.

What temperature does a gas theoretically reach zero volume?

Extrapolating the straight line gives −273.15 °C, or 0 K. Real gases liquefy long before that, so the prediction is a limit rather than an observation.

How much does a gas expand from 20 °C to 40 °C?

From 293.15 K to 313.15 K is a 6.8% rise, so 1 L becomes 1.068 L. The Celsius difference of 20 looks like a doubling; the absolute difference is far smaller.

Does the amount of gas matter?

It must stay constant, which is why the container has to be sealed. Leak or inject gas and you need the ideal gas law, PV = nRT, which carries the mole count explicitly.

Method and sources

Calculation basis

Physical constants follow CODATA 2022 recommended values, and formulas follow standard physics definitions.

Last updated: November 17, 2026
Formula & data sources
  • Charles’s law (V₁/T₁ = V₂/T₂) at constant pressure.

Cite this page

Reference formats
APA 7CalcSeed. (2026, November 17). Charles's Law Calculator. https://calcseed.com/c/scientific/charles-law-calculator/
MLA 9"Charles's Law Calculator." CalcSeed, 17 Nov. 2026, calcseed.com/c/scientific/charles-law-calculator/.
ChicagoCalcSeed. "Charles's Law Calculator." Last modified November 17, 2026. https://calcseed.com/c/scientific/charles-law-calculator/

Related calculators