Buffer Capacity Calculator
Enter the total buffer concentration, the acid pKa and the pH to estimate the buffer capacity.
What buffer capacity measures
Buffer capacity, written β, is the amount of strong acid or base a litre of solution absorbs per unit of pH shift. It is a slope, not a total: it tells you how hard the solution pushes back at the pH it is currently sitting at. This calculator returns β in moles per litre per pH unit from the total buffer concentration, the acid pKa and the working pH.
C is the total concentration of the buffer pair, acid plus conjugate base. Ka is 10−pKa and [H⁺] is 10−pH. The 2.303 factor is the natural-log-to-base-10 conversion, because pH is logarithmic and the underlying Henderson–Hasselbalch relation is not.
The fraction on the right is a product of two populations divided by their sum squared, which is why it peaks when the two are equal and falls off symmetrically either side. Nothing here depends on the identity of the buffer beyond its pKa and its concentration.
Why the peak sits exactly at pH = pKa
At pH = pKa, the acid and its conjugate base are present in equal amounts, so each can absorb whichever disturbance arrives. Half the molecules are ready to take up a proton and half are ready to release one. That balance is the maximum resistance the pair can offer.
Substitute Ka = [H⁺] into the formula and the fraction collapses to one quarter, leaving βmax = 2.303 × C ÷ 4 = 0.576 × C. Every buffer, regardless of its pKa, peaks at 57.6% of its total concentration in these units. That single number is the most useful thing on this page.
Move away from the pKa and the balance tips. At one pH unit below, the acid outnumbers the base roughly ten to one, and the mixture has far less ability to soak up added base. The capacity falls to about a third of peak, which is why a buffer is normally used within one unit of its pKa.
Worked example at the defaults
The defaults are 0.1 M total acetate buffer, pKa 4.76, at pH 4.76. The pH equals the pKa, so the capacity is at its maximum: 0.576 × 0.1 = 0.0576 mol/L per pH unit, which is the figure the calculator returns.
Read that as a practical quantity. One litre of this buffer absorbs 0.0576 mol of strong base, or 57.6 mL of 1 M NaOH, before its pH climbs by a full unit. Half a litre absorbs 0.0288 mol, about 29 mL of the same 1 M base.
Now shift the pH to 5.76, one unit above the pKa, keeping the concentration. The capacity drops to about 0.019 mol/L per pH unit. The solution is still buffered, but it takes roughly a third as much acid or base to move it, which is the difference between a robust assay and one that drifts.
How fast capacity falls away from the pKa
| pH relative to pKa | Fraction of peak | β at C = 0.1 M |
|---|---|---|
| −1.0 | 0.33 | 0.019 |
| −0.5 | 0.73 | 0.042 |
| 0 | 1.00 | 0.058 |
| +0.5 | 0.73 | 0.042 |
| +1.0 | 0.33 | 0.019 |
| +2.0 | 0.04 | 0.002 |
Half a unit off the pKa still leaves 73% of the peak capacity, which in practice is close enough to call it buffered. Two units off leaves 4%, at which point you are mostly measuring the water. The table is symmetric because the formula treats acid and base populations the same way.
Picking a buffer for the pH you need
| Buffer | pKa at 25 °C | Useful range | Typical use |
|---|---|---|---|
| Acetate | 4.76 | 3.8–5.8 | Protein precipitation, vinegar assays |
| MES | 6.10 | 5.5–6.7 | Electrophoresis running buffers |
| Phosphate, second | 7.20 | 6.2–8.2 | Cell culture, enzyme assays |
| HEPES | 7.55 | 6.8–8.2 | Mammalian cell work |
| Tris | 8.06 | 7.0–9.0 | DNA work, SDS-PAGE |
| Borate | 9.24 | 8.2–10.2 | Capillary electrophoresis |
| Glycine | 9.78 | 8.8–10.8 | Western blot transfer |
Each entry spans roughly two pH units, one either side of its pKa, which is the zone where capacity stays above about a third of peak. Pick the row whose pKa is closest to your target pH and you get the most capacity for the least buffer. A 0.1 M phosphate buffer at pH 7.20 gives 0.058, while forcing acetate to hold pH 7.20 drops it to roughly 0.0008 — about seventy times less capacity from chemistry alone.
What changes the number in a real lab
- Total concentration: capacity is directly proportional, so 0.2 M doubles the 0.0576 of a 0.1 M acetate buffer.
- pH versus pKa: every 0.5 unit of offset costs about 27% of capacity, on either side.
- Temperature: Tris pKa falls about 0.028 per °C, so 8.06 at 25 °C becomes 7.72 at 37 °C and the buffer drifts a third of a unit below its nominal setting.
- Ionic strength: high salt screens the charges and typically lowers measured capacity by 10–20% against the ideal formula.
- Dissolved CO2: an open vessel equilibrating with air picks up carbonic acid, which pulls a pH 8 buffer downward and burns capacity without any deliberate addition.
Where the estimate is optimistic
The formula describes a single monoprotic acid in pure water. Real buffers often have a second ionisation, so phosphate at pH 7 is buffered by both the second and third equilibria and the single-pKa model understates capacity somewhat. Polyprotic buffers also show two peaks rather than one, and the dip between them can be 30–40% below the higher peak.
The bigger gap is the linear assumption. β is defined as the derivative of concentration with respect to pH, so it is only valid over a small step. Over a full pH unit the true titration curve bends, and the amount of base needed is not simply β times one. Treat the output as the local slope at the stated pH, and integrate or titrate if you need the full curve.
Working concentration versus stock
Capacity scales with the concentration in the final vessel, not the stock bottle. Dilute a 1 M stock tenfold into the assay and the capacity falls from 0.576 to 0.0576 at peak. This catches people who calculate a generous buffer, then add 2 mL of it to a 100 mL reaction and wonder why the pH wanders.
Temperature drift beats the buffer
A buffer can have excellent capacity and still fail because its pKa moves with temperature faster than the experiment tolerates. Tris is the worst offender in common use: a buffer prepared and adjusted to pH 8.06 at 25 °C will sit near pH 7.72 in a 37 °C incubator, a shift that consumes most of the usable range before anything is added.
Frequently asked questions
When is buffer capacity highest?
When pH equals the pKa. At that point the acid and conjugate base are equal, and capacity peaks at 0.576 × C, which is 0.0576 mol/L per pH unit for a 0.1 M buffer.
How do I make a stronger buffer?
Raise the total concentration or move the pH closer to the pKa. Doubling 0.1 M to 0.2 M doubles 0.0576 to 0.115; moving from pKa + 1 to pKa triples capacity from 0.019 to 0.058.
What units does buffer capacity use?
Moles of strong acid or base per litre per pH unit. A value of 0.0576 means 0.0576 mol added to one litre shifts the pH by one unit.
How much NaOH can 1 L of 0.1 M acetate buffer absorb?
At pH 4.76, the pKa, about 0.0576 mol, which is 57.6 mL of 1 M NaOH before the pH moves a full unit.
Why does capacity fall off away from the pKa?
One form of the pair dominates, so there is little of the other left to absorb a disturbance. At one unit away only about 33% of the peak capacity remains.
Does temperature affect buffer capacity?
It shifts the pKa, which moves the working point. Tris loses about 0.028 pKa units per °C, so 8.06 at 25 °C becomes 7.72 at 37 °C.
What is the best buffer for pH 7.4?
Phosphate at pKa 7.20 or HEPES at 7.55, both within 0.35 of the target. Either gives close to peak capacity, and 0.1 M HEPES returns about 0.056 at pH 7.4.
Is buffer capacity the same as buffer strength?
It is the quantitative version of it. Strength is vague; capacity is the measured slope, and 0.0576 is a specific, comparable figure rather than a description.
Does the calculator work for a base buffer?
It works for any weak acid and its conjugate base, which covers most basic buffers too. Enter the conjugate acid pKa, such as 9.25 for ammonia, and the pH you are holding steady.
Why is my measured capacity lower than calculated?
Ionic strength, CO2 uptake and a second ionisation all pull the real value below the ideal one, typically by 10–20% at 0.1 M.
Method and sources
- Buffer capacity β = 2.303 C Ka[H⁺] / (Ka + [H⁺])².