Sheet Metal Flat Length Calculator
Enter the bend angle, inside radius, thickness, K-factor and the two leg lengths to find the bend allowance, bend deduction and flat length.
What this calculator returns
This tool returns three numbers in millimetres: the bend allowance, the bend deduction and the flat blank length. At the defaults — a 90° bend, 1 mm inside radius, 1 mm thickness, K-factor 0.33, two 25 mm legs — it returns BA 2.09 mm, BD 1.91 mm and a flat length of 48.09 mm. The flat length is what the laser or punch cuts before the part ever reaches the brake.
Bend allowance, deduction and flat length
Bending stretches the outside and compresses the inside. Somewhere between them sits the neutral axis, at fraction K of the thickness measured from the inside surface, and its length does not change. Bend allowance is that arc length: the bend angle in radians times the neutral radius (R + K·t). For 90°, the angle is π/2 = 1.5708 rad, and with R = 1, K = 0.33 and t = 1 the neutral radius is 1.33 mm, giving BA = 2.089 mm.
Bend deduction is a different measurement. Legs are dimensioned to the outside mould line, where the two outer faces would meet if extended, so each leg includes a wedge of material that the bend consumes. That wedge, measured from the mould line to the tangent point, is (R + t)·tan(θ/2) per side. Subtract the bend allowance and what remains is the deduction: 2 × 2 × tan(45°) − 2.089 = 4.000 − 2.089 = 1.911 mm. Flat length = 25 + 25 − 1.911 = 48.089 mm.
Worked example at the defaults
Take a 90° channel with 25 mm outside legs, 1 mm 304 sheet, 1 mm inside radius. Neutral radius = 1 + 0.33 × 1 = 1.33 mm. Arc = 1.5708 × 1.33 = 2.089 mm. Mould-line offset per side = (1 + 1) × tan(45°) = 2.000 mm, so the two offsets total 4.000 mm and BD = 4.000 − 2.089 = 1.911 mm. Cut the blank at 48.09 mm.
If you cut 50 mm instead — the naive sum of the legs — each leg finishes about 0.95 mm long and the part is 1.91 mm oversize across the outside. That is not a tolerance issue on a bracket; it is a fit issue on anything that nests. Conversely, using the bend allowance of 2.09 as the deduction gives 47.91 mm, which is 0.18 mm short and equally wrong.
K-factor by radius-to-thickness ratio
| R/t ratio | Typical K-factor | Neutral radius at t = 1 mm | BA at 90° |
|---|---|---|---|
| 0.5 | 0.28 | 0.78 mm | 1.23 mm |
| 1.0 | 0.33 | 1.33 mm | 2.09 mm |
| 2.0 | 0.40 | 2.80 mm | 4.40 mm |
| 3.0 | 0.45 | 3.45 mm | 5.42 mm |
| 5.0 | 0.50 | 5.50 mm | 8.64 mm |
Small radii relative to thickness push the neutral axis inward, because the outer fibres stretch more severely and the inner ones compress less. Large radii approach the geometric centreline, where K = 0.5 and BA = θ × (R + t/2). Using 0.33 on a 5 mm radius in 1 mm sheet understates the allowance by 2.43 mm, which shows up as short legs after forming.
Flat length by bend angle
| Bend angle | Bend allowance | Bend deduction | Flat length, 2 × 25 mm legs |
|---|---|---|---|
| 30° | 0.70 mm | 0.38 mm | 49.62 mm |
| 45° | 1.04 mm | 0.61 mm | 49.39 mm |
| 60° | 1.39 mm | 0.92 mm | 49.08 mm |
| 90° | 2.09 mm | 1.91 mm | 48.09 mm |
| 120° | 2.79 mm | 4.14 mm | 45.86 mm |
Deduction grows faster than allowance once the bend passes 90°, because the mould-line offsets expand as tan(θ/2) while the arc grows linearly. At 120° the deduction is 4.14 mm and the blank is 45.86 mm, nearly 4 mm shorter than the leg sum. By 150° the deduction reaches 11.45 mm against an allowance of 3.48 mm, and at 180° the mould lines never intersect at all — a hem needs its own formula.
What moves the flat length
- K-factor. Raising K from 0.33 to 0.40 at the defaults adds 0.11 mm of allowance and 0.11 mm of flat length.
- Inside radius. Larger radius means a longer arc: R 1 mm to 2 mm adds 1.57 mm at 90°.
- Thickness. Enters through both K·t and the mould-line offset: 1 mm to 1.5 mm shrinks the flat from 48.09 to 47.35 mm.
- Bend angle. A 90° bend consumes 1.91 mm of blank; a 45° bend consumes 0.61 mm.
- Material and temper. Springback changes the effective angle, and high-strength steel needs a larger K than mild.
Mistakes that scrap the blank
Subtracting the bend allowance instead of the deduction
These are not interchangeable and differ by 0.18 mm at the defaults. Bend allowance is an arc length used inside a developed-length calculation from tangent points; bend deduction is what comes off the outside leg sum. On a 1 mm part, 0.18 mm is 18 percent of thickness and enough to miss a +/-0.1 mm flat pattern tolerance.
Measuring legs to the inside instead of the outside
Inside dimensions already exclude the material the bend consumes, so subtracting a deduction double-counts the corner. A 25 mm inside leg on both sides gives a flat of 50 − 2 × 2 − 2.09, not 48.09. Confirm which convention the drawing uses before typing numbers; mixing them is the most common cause of a part that comes out 4 mm long.
Using one K-factor for every material
The 0.33 default suits mild steel at R ≈ t. Aluminium 5052 in the same geometry sits nearer 0.40, which shifts the flat length by about 0.1 mm; 304 stainless at 0.45 shifts it 0.19 mm in the other direction. On a 1 mm part that is the difference between a press fit and a rattle.
Bend tables versus calculated values
Most shops own a bend table generated by physically bending sample coupons and measuring the result. Those tables beat any formula because they capture the tooling, the material lot and the operator’s method. Use this calculator to sanity-check a table, to work in a material the table does not cover, or to understand why a table entry is what it is. If the table says 48.20 mm and the formula says 48.09 mm, believe the table and use the formula to explain the 0.11 mm difference — that is a K-factor of about 0.39, not an error.
Frequently asked questions
What is the K-factor in sheet metal?
The neutral axis position as a fraction of thickness from the inside surface. It runs 0.28 at R/t = 0.5 up to 0.50 at R/t = 5, and 0.33 is a reasonable default for mild steel at R ≈ t.
What is the difference between bend allowance and bend deduction?
Bend allowance is the arc length along the neutral axis, 2.09 mm at the defaults. Bend deduction is what you subtract from outside leg lengths to get the flat, 1.91 mm here. They differ by 0.18 mm.
What is the flat length of a 90 degree bend with 25 mm legs?
48.09 mm for 1 mm sheet, 1 mm inside radius and K 0.33. The leg sum is 50 mm and the bend deduction is 1.91 mm.
Why does the K-factor vary?
It depends on the R/t ratio, material and tooling. Thin sheet with a tight radius compresses the inside more, pulling the neutral axis to 0.28; wide radii approach 0.5.
Do I use inside or outside dimensions?
This formula takes outside dimensions to the mould line. Inside dimensions already exclude the corner material, so subtracting a deduction from them double-counts and produces a blank about 4 mm short at the defaults.
How much does 1 mm of thickness change the flat length?
Going from 1 mm to 1.5 mm at 90° and R1 takes the flat from 48.09 to 47.35 mm, about 0.74 mm shorter, because thickness enters the allowance and both mould-line offsets.
What is the flat length for a 120 degree bend?
45.86 mm with 25 mm legs. The bend allowance is 2.79 mm but the deduction grows to 4.14 mm, so the blank is shorter than at 90°.
Should I trust a shop bend table over this calculator?
Yes when the table covers your material and tooling. Tables are measured, formulas are modelled. Use the calculator to check a table or to extend it to a new material.
Why is my formed part 2 mm oversize?
Most likely no bend deduction was applied. Cutting the leg sum of 50 mm instead of 48.09 mm leaves each leg about 0.95 mm long and the part 1.91 mm wide.
Method and sources
- Bend allowance: BA = θ·(π/180)·(R + K·t); bend deduction: BD = 2(R+t)·tan(θ/2) − BA; flat length = L1 + L2 − BD.